Drafts affect infrared thermography results

Thermographic images of a horse's forelegs; no draught (left) and draught of 1.3 to 2.6 metres per second (right). After 2:30 minutes the right hand leg has cooled down considerably.
Thermographic images of a horse’s forelegs; no draught (left) and draught of 1.3 to 2.6 metres per second (right). After 2:30 minutes the right hand leg has cooled down considerably. © Vetmeduni Vienna/Westermann

Infrared thermography is extremely sensitive to even very gentle drafts, Austrian researchers have found.

A wind speed of less than 1 metre per second can cause a drop in measured temperature of about 0.6°C, while winds of 1.3-2.6 metres per second can cause a drop of 1.5°C. Winds of 3-4 metres per second can cause a drop of 2.1°C.

The researchers warned that the discrepancies were more than sufficient to lead to a wrong diagnosis.

One of the study’s authors, Simone Westermann, from the University of Veterinary Medicine in Vienna, said she was keen to note the relevance of her work for vets who worked on horses.

“It turns out that it is not too important to be sure that the camera is in exactly the correct position before taking measurements. But it is essential to perform thermography on horses in a room that is completely free of draughts. If you don’t, your diagnosis will be completely unreliable.”

Since its introduction about 50 years ago, infrared thermography is increasingly being applied to investigate the cause of lameness in horses.

The equipment is easy to handle and the method is fast and safe, both for the animal and for the vet.

The work by Westermann shows that the technique is surprisingly tolerant of variation in the position of the equipment – that is, how far from the horse and at what angle to the animal the infrared camera is held.

However, it is extremely important to ensure that the horse is not standing in a draught as even barely detectable wind speeds are sufficient to effect the measurements dramatically.

The findings are published in two articles, one in the Journal of the American Veterinary Medical Association and the other in the Equine Veterinary Journal.

Infrared thermography is fast and safe and is based on a simple idea. The horse’s body surface emits infrared radiation that can be detected by an infrared camera, which is both easy and inexpensive to use.

The camera produces a coloured image that shows the variation in surface temperature across the area investigated.
The temperature is directly related to the presence of blood vessels near the skin, so the method can detect local inflammatory lesions or regions of modified blood flow and thus help localize the origin of lameness.

The theory is clear, but to date there have been comparatively few investigations into the reliability of the method.

Furthermore, it is important to note that in practice trivial matters such as time constraints and movement of the horse can cause changes in both camera angle and distance of the camera to the area of the horse being investigated. The effect to which these changes affect the results of thermographic imaging was unknown.

Finally, although it is generally accepted that thermographic imaging of horses should be performed in draught-free surroundings, there have not been any published studies on the effect of airflow on the results.

These issues were tackled by Westermann, who works in the university’s Clinical Unit of Equine Surgery, together with colleagues at the university and with Adrian Ion at the Vienna University of Technology.

The scientists found that the method was highly reproducible and was less sensitive to variations in camera position and angle than might be expected. In fact, the results were almost completely unaffected by 20-degree changes in camera angle and increases of up to 50cm in the distance of the camera from the animal.

At a distance of 1 metre from the horse a 20-degree change in camera angle corresponds to about 35cm. This represents the effective horizontal tolerance in positioning of the camera. As Westermann says: “vets should have little difficulty in remaining within this limit, so the method is applicable in practice.”

Surprisingly, the results showed that horses’ left and right forelimbs show minor differences in temperature and Westermann cautions that “it might be important to take these into account before reaching a final diagnosis”.

The technique is thus reliable and robust, at least in terms of variation in where the camera is located.

However, it turned out to be extremely sensitive to even very gentle drafts.

 

The paper, The effect of airflow on thermographically determined temperature of the distal forelimb of the horse, by Simone Westermann, Christian Stanek, Johannes P. Schramel, Adrian Ion and Heinz H. F. Buchner will shortly appear in print in the Equine Veterinary Journal but is already available for early view online (doi: 10.1111/evj.12019).

The abstract of the original paper on the effect of draught on thermography measurements is available online (full text for a fee or with a subscription): http://dx.doi.org/10.1111/evj.12019

The paper, Effects of infrared camera angle and distance on measurement and reproducibility of thermographically determined temperatures of the distolateral aspects of the forelimbs in horses, by Simone Westermann, Heinz H. F. Buchner, Johannes P. Schramel, Alexander Tichy and Christian Stanek is published in the current issue of the Journal of the American Veterinary Medical Association (Vol. 242, pp. 388-395).

The abstract of the original paper on camera position is also available online (full text for a fee or with a subscription):